Skip to content
eBook Charts
UK
Two Cases with Unusual Vancomycin Measurements (Clinical Case Study) (Case Study)

Two Cases with Unusual Vancomycin Measurements (Clinical Case Study) (Case Study)

Clinical Chemistry

£2.99

Buy on Amazon View on Apple Books

Prefer it in print? See every format on Amazon →

Price on Apple Books. Amazon’s price may differ.

Read a lot? Try Kindle+ * · Compare subscriptions

Published
Genres
ChemistryScience & Nature

Description

CASE Patient A was a 68-year-old woman with a history of lymphoplasmacytic lymphoma who presented after several weeks of mucosal bleeding. On admission, her cancer involved 95% of bone marrow cells. She was pancytopenic and febrile (38.3 [degrees]C). Leukocyte count was 0.39 x [10.sup.3]/[micro]L (neutrophils, 0.03 x [10.sup.3]/ AL), hematocrit 25%, platelet count 21 x [10.sup.3]/[micro]L, relative serum viscosity 2.3 (reference interval, 1.4-1.8), blood urea nitrogen 6.4 mmol/L (18 mg/dL), creatinine 62 [micro]mol/L (0.7 mg/dQ, and estimated glomerular filtration rate 60 mL/min/1.73 [m.sup.2]. She had an IgM[KAPPA] monoclonal component of 42.8 g/L. This patient was started on vancomycin 1 g intravenously (IV) every 12 h, ceftazidime 2 g IV every 8 h, and a course of chemotherapy. On day 3 after the beginning of antibiotic treatment, a trough specimen was collected for measurement of vancomycin. The concentration, measured with a Beckman Coulter Synchron competitive turbidimetric immunoassay, was 0.1 mg/L. The result, which was incompatible with ongoing vancomycin therapy, signaled a problem to the technologist. No analytical issues were evident upon review of calibration, controls, and results for other chemistry tests performed on the same specimen. In an attempt to resolve an apparent falsely low result, a 1:1 mix of the specimen was made with the Beckman liquid comprehensive control serum (level 3, 30.4 mg/L) and demonstrated near complete recovery (result of mix after adjusting for dilution, 28.6 mg/L). However, a 1:1 mix with pooled patient serum containing vancomycin (11 mg/L) led to only 15% recovery (result of mix after adjustment for dilution, 1.7 mg/L). The specimen was subsequently sent to another laboratory, where a vancomycin concentration of 9.8 mg/L was measured by use of a competitive enzyme-finked immunoassay (Emit, Olympus).
Persistent Increase in Aspartate Aminotransferase in an Asymptomatic Patient (Clinical Case Study) (Case Study)Clinical Chemistry£2.99Cirrhosis Originally Diagnosed As Nonalcoholic Steatohepatitis (Clinical Case Study)Clinical Chemistry£2.99Low Vitamin D Status in a Representative Sample of Youth from Quebec, Canada (Endocrinology and Metabolism)Clinical Chemistry£2.99New Horizons for Diagnostic Applications of Circulating Nucleosomes in Blood?(Editorial)Clinical Chemistry£2.99Microarray Technology and Applications in the Arena of Genome-Wide Association.Clinical Chemistry£2.99A Girl with Goiter and Inappropriate Thyroid-Stimulating Hormone Secretion (Clinical Case Studies) (Clinical Report)Clinical Chemistry£2.99Aspirin Responsiveness in Healthy Volunteers Measured with Multiple Assay Platforms.Clinical Chemistry£2.99Why a Cluster is Truly a Cluster: Insulin Resistance and Cardiovascular Disease (Perspective)Clinical Chemistry£2.99Estimating LDL Apob: Infomania Or Clinical Advance?(Editorial) (Clinical Report)Clinical Chemistry£2.99Association Between the UGT1A1 Ta-Repeat Polymorphism and Bilirubin Concentration in Patients with Intermittent Claudication: Results from the CAVASIC Study (Molecular Diagnostics and Genetics) (Clinical Report)Clinical Chemistry£2.99Factors Associated with Paraoxonase Genotypes and Activity in a Diverse, Young, Healthy Population: The Coronary Artery Risk Development in Young Adults (CARDIA) Study (Lipids, Lipoproteins, And Cardiovascular Risk Factors)Clinical Chemistry£2.99SELDI-TOF MS Whole Serum Proteomic Profiling with IMAC Surface Does Not Reliably Detect Prostate Cancer (Proteomics and Protein Markers) (Clinical Report)Clinical Chemistry£2.99